Symptom
Heavy build up of frost,
possibly also on the door
seal.
The compressor does not
start immediately after
changing the temperature
setting.
Temperature cannot be set
Water on the floor or on
storage shelves.

Changing the light bulb

Warning! There is a risk of electric shocks! Before changing the light
bulb, switch off the appliance and unplug it, or disconnect from the
mains supply.
Light bulb data: 220-240 V, max. 25 W
1. To switch off, press the ON/OFF button until the mains power light
extinguishes.
2. Unplug the mains plug.
3. To change the light bulb, undo the
screw.
4. Press the light bulb cover as shown and
slide it towards the rear of the appli-
ance.
5. Change the faulty light bulb.
6. Refit the light bulb cover and the screw.
7. Put the refrigerator back into operation.
Possible Cause
Door seal is not air tight
(possibly after reversing
the door).
This is normal, no error has
occurred.
COOLMATIC or FROSTMAT-
IC functions switched on.
Water drain hole is
blocked.
What to do if...
Remedy
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.
The compressor starts after
a period of time.
Switch off COOLMATIC or
FROSTMATIC manually, or
wait to set the tempera-
ture until the function has
reset automatically (refer
also to COOLMATIC/FROST-
MATIC section).
See the "Cleaning and
Care" section.