IBM 9234CNU - Lotus Foundations Server Service Manual page 126

Lotus foundations appliance, type 9234 cnu and 9234 dnu problem determination and service guide
Table of Contents

Advertisement

The following table describes the problems that are indicated by various
combinations of the power-supply LEDs and the power-on LED on the front
information panel and suggested actions to correct the detected problems.
108
Lotus Foundations Appliance, Type 9234 CNU and 9234 DNU: Problem Determination and Service Guide
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See Chapter 3, "Parts listing, Lotus Foundations Appliance Type 9234," on page 19
to determine which components are customer replaceable units (CRU) and which
components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must
be performed only by a trained service technician.
Power-supply
Front
LEDs
information
panel power-on
AC
DC
LED
Off
Off
Off
Lit
Off
Off
Lit
Lit
Off
Lit
Lit
Flashing
Lit
Lit
Lit
Description
Action
No power to the
1. Check the ac power to the server.
server, or a
2. Make sure that the power cord is
problem with the
connected to a functioning power
ac power source.
source.
3. Remove one power supply at a
time.
DC source or
1. Make sure that the power supply is
power supply
connected to the power backplane.
power problem.
2. Remove and replace one power
supply at a time.
3. View the system-error log (see
"Error logs" on page 82).
Standby power
1. View the system-error log (see
problem.
"Error logs" on page 82).
2. Remove one power supply at a
time.
3. (Trained service technician only)
Replace the power backplane.
System
1. View the system-error log (see
power-on
"Error logs" on page 82).
problem.
2. Make sure that the power cables
are seated correctly.
3. Press the power-control button on
the control-panel.
4. Remove the optional Remote
Supervisor Adapter II SlimLine, and
try to turn on the server.
5. (Trained service technician only)
Reseat the system board.
6. (Trained service technician only)
Replace the system board.
The power is
No action is necessary.
good.

Advertisement

Table of Contents
loading

This manual is also suitable for:

9234dnu

Table of Contents