NX-5A (Powered Near Field Monitor)
Output level control
VOL
MAX
(0dB)
Tweeter level control
You can use the TWEETER con-
trol to adjust the tweeter level
0dB
TWEETER
within the range of +/- 3 dB.
LEVEL
The center position (0 dB) is
the nominal position. Turning
the control right boosts the
-3
+3
tweeter level, while turning
it left drops the level (see the
graph right). When the unit is
shipped, the TWEETER control
is set to the center (0 dB).

Names and functions

1
2
VOL
MAX
[0dB]
0dB
3
TWEETER
LEVEL
-3
+3
LO FREQ
4
+2dB
0
-2
INPUT
5
UNBAL
-10dBV
6
1:G
2:H
3:C
BAL
+4dBu
7
POWER
ON
8
OFF
AC IN
9

Control positions

Rotating the VOL control clock-
wise increases the output level.
1. Power LED
Lights when power is turned on.
2. Output level control
Adjusts output level.
3. Tweeter level control
Adjusts tweeter level within a +/- 3dB range.
4. Low-frequency EQ control
Adjusts low frequency characteristics (around 55Hz
range) within a +/- 2dB range.
5. Unbalanced input terminal (Phone jack)
Accepts -10dBV unbalanced input.
6. Balanced input terminal (XLR-3-31 type)
Accepts +4dBu balanced input (hot pin is #2).
<CAUTION>:
The balanced (XLR) and the unbalanced
(phone) input connectors cannot be used simultaneously.
When the unbalanced connector is plugged, the unbalanced
input takes priority and the balanced input is disabled.
7. Heatsink
<CAUTION>:
If you use the NX-5A for a long time, the
heatsink gets extremely hot. Do not touch the heatsink
in such a condition.
8. Power switch
Turn the power on or off. Make sure that the output
level control of the connected equipment is set to
minimum when turning on the power.
9. AC IN connector
Connects the AC cord provided.
Correction to low frequency characteristics
110
Wf +2dB
90
Wf -2dB
70
(dB)
50
20
50
90
100
(Hz)
6
This LO FREQ switch permits
c o r r e c t i o n o f t h e l o w f r e -
quency (around 55Hz range)
response by +/- 2dB.
This control is factory-set the
"0" position. By setting the
switch at the "+2dB" position,
the 55Hz response will be en-
hanced. Setting to the "-2dB",
the response will be attenu-
ated by 2dB.
500
200
1k
2k
5k
Tw +3dB
Tw -3dB
10k
20k
50k