Configuring A Fex With A Layer 3 Host Interface; Configuring A Host Interface In A Vpc Topology Connected To Two Fexs - Cisco SD2008T-NA Configuration Manual

Nx-os fabric extender
Hide thumbs Also See for SD2008T-NA:
Table of Contents

Advertisement

Configuration Examples

Configuring a FEX with a Layer 3 Host Interface

This example shows how to configure a Fabric Extender with a Layer 3 host interface (at the interface level,
subinterface level, port channel level, and port channel subinterface level):
Layer 3 Configuration
config t
interface ethernet 101/1/1
no switchport
ip address 192.0.1.1/24
Mtu 9000
no shutdown
Layer 3 Host Interface Port Channel Configuration
config t
interface ethernet 101/1/1-2
no switchport
channel-group 12
no shutdown
interface port-channel 12
ip address 192.0.3.1/24
mtu 2000
no shutdown
The VLAN used in the Layer 3 host interface (HIF) or host interface port channel (HIFPC) subinterface
Note
has only local significance to its parent interface. The same VLAN ID can be reused between Layer 3
subinterfaces in the same switch or VDC.

Configuring a Host Interface in a vPC Topology Connected to Two FEXs

This example shows how to configure a host vPC with a FEX (host vPC attached to 2 different FEXs):
Switch 1 Configuration
config t
feature lacp
int e101/1/1-2
channel-group 12 mode active
no shutdown
Int port-channel10
switchport
switchport mode trunk
switchport trunk allowed vlan 1-20
vpc 10
Cisco Nexus 2000 Series NX-OS Fabric Extender Software Configuration Guide
24
Configuring the Fabric Extender
Layer 3 Sub-interface Configuration
config t
interface ethernet 101/1/1.12
ip address 192.0.2.1/24
encapsulation dot1Q 12
mtu 850
no shutdown
Layer 3 Host Interface Port Channel Sub-interface
Configuration
config t
interface ethernet 101/1/1-2
no switchport
channel-group 12
no shutdown
interface port-channel 12.14
ip address 192.0.4.1/24
encapsulation dot1Q 14
mtu 1700
no shutdown
Switch 2 Configuration
config t
feature lacp
int e101/1/1-2
channel-group 12 mode active
no shutdown
Int port-channel10
switchport
switchport mode trunk
switchport trunk allowed vlan 1-20
vpc 10
OL-25816-02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sge2000Slm2024t-naNexus 2000 series

Table of Contents