Rack-mounting

The air is as free from dust as possible.
The Switch is situated away from sources of conductive (electrical)
dust, for example laser printers.
The unit is installed in a clean, air conditioned environment.
The AC supply used by the Switch is separate to that used by units
that generate high levels of AC noise, for example air conditioning
units.
No more than four Switch units are placed on top of one another, if
the units are free-standing.
The Switch 4050 and 4060 are 2U high and will fit in most standard
19-inch racks.
CAUTION: Disconnect all cables from the Switch before continuing.
Remove all self adhesive pads from the underside of the Switch if they
have been fitted.
CAUTION: If you use a shelf or support ensure that it will not obstruct
the air flow through the side panels of the Switch.
To rack-mount your Switch:
1 Place the Switch the right way up on a hard flat surface, with the front
facing towards you.
2 Locate a securing bracket over the mounting holes on one side of the
Switch, as shown in
3 Insert the four screws and tighten with a suitable screwdriver.
Figure
4.
Rack-mounting
23