MAINTENANCE
Periodic maintenance
and adjustment is necessary to keep the generator/
welder in good operating condition. Perform the service and inspection at the
intervals shown in the Maintenance
schedule below.
m
Exhaust gas contains poisonous
carbon monoxide.
t
L -
.
Shut off the engine before performing any maintenance.
If the engine
must be run, make sure the area is well ventilated.
pmicq
Use only genuine HONDA parts or their equivalent for
maintenance or repair. Replacement parts which are not of equivalent
quality may damage the generator.
MAINTENANCE SCHEDULE
REGULAR SERVICE PERIOD
Performed at every indicated month
or operating hour interval, whichever
comes first.
ITEM
Engine oil
Check level
Change
Air cleaner
Check
Clean
GFCI receptacle
Check
Sediment
Cup
Clean
Spark pulg
Check-Clean
Spark Arrester
Clean
Valve clearance
Check-Adjust
Fuel tank and strainer
Clean
Check
Fuel line
(Replace if
necessary)
Every 2 years (2)
Every
year
or
300 Hrs.
(3)
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by an authorized Honda generator dealer, unless the
owner has the proper tools and is mechanically
proficient. See the Honda Shop Manual.
(3) For professional commercial use, log hours of operation to determine proper maintenance