2.4 - Configuration

Configuration of the DriveRack units is done in Unit view. The DriveRack 220i configuration can
be changed by clicking on the CONFIG button. Once the CONFIG button has been clicked, the
modules can be changed by right clicking on the module to be changed. For example, if you want to
change the processing module in one of the inserts, you simply right-click on that module and you will
be able to select another processing block as well as unlink that module (if it is stereo linked). To link
modules in stereo, click on one of the module that you want to link. While holding the Ctrl button click
the other module that you want to link it to; both modules should now be highlighted. By right-clicking
on either module you can now select LINK. Once the desired configuration is created you must click the
CONFIG button once more to load the configuration.

2.5 - Editing

To edit a processing module double click on that module. Adjust the module to taste; make sure that
the module is engaged, this is usually indicated by the module on button in the upper left corner of the
parameter section. Although process editing is done in real-time, the changes can either be discarded or
accepted by selecting the OK or CANCEL button.