D e f i n i n g t h e F o r m a t H e a d e r
Use this section with either XML-enabled option. A Format Header
begins a format file.
Syntax
{F,format#,action,device,measure,length,
width,"name"¦
F1. F
F2. format#
F3. action
F4. device
F5. measure
F6. length
F7. width
F8. "name"
Example {F,1,A,F,E,300,200,"XML_FORMAT_ONE"¦
Defines the name for format 1 as XML_FORMAT_ONE.
2 Quick Reference
Format Header.
Number from 1-999 to identify the format.
Enter A to add a new format to the printer.
Format storage device. Use F (Flash).
Unit of measure: E (English), M (Metric), or
G (Graphic Dots).
Printer
Unit of Measure
9855/9860
English (1/100 inch)
Metric (1/10 mm)
203 dpi Dots
Refer to the optional Packet Reference Manual for
more information.
Length in selected units. Measure supply from the
leading edge of one label to the leading edge of the
next label. The leading edge is the edge that exits
the printer first.
Width, from left to right, in selected units.
Format name, 1-256 characters, enclose within
quotation marks. The name can contain special
characters, excluding non-printable control characters
and the quotation mark (").
Length
Width
75-1600
32-400
191-4064
81-1016
152-3248
62-812