• NULL: Allows you to enable (ON) or disable (OFF) the null measurement
• NULL VALUE: Allows you to view and edit the null value (if enabled).
• UNITS: Allows you to select the temperature scale: Celsius (select C),

Configuring Capacitance Measurements

For capacitance measurements, your configuration menu choices are: RANGE,
NULL and NULL VALUE.
• RANGE: Allows you to let the multimeter automatically select the range using
• NULL: Allows you to enable (ON) or disable (OFF) the null measurement
• NULL VALUE: Allows you to view and edit the null value (if enabled).

Continuity and Diode Tests

There are no parameters to configure, nor any menus for these functions.
• Continuity Test. The range and resolution are fixed for continuity tests.
• Diode Test. The range and resolution are fixed for diode tests.
34410A/11A/L4411A User's Guide
feature, which measures the difference between a stored null value and the
input signal.
Fahrenheit (select F), or Kelvin (select K).
the autoranging feature (select AUTO), or you may select a fixed range
(select MANUAL).
feature, which measures the difference between a stored null value and the
input signal.
The range is 1 kΩ (a 2-wire resistance measurement).
The meter beeps (even if beep is disabled) for each measurement that is
less than or equal to the continuity threshold (which is 10 Ω), and the
actual resistance reading is displayed on the front panel.
From 10 Ω to 1.2 kΩ the meter displays the actual resistance reading with
no beep. If the reading exceeds 1.2 kΩ, the meter displays "OPEN" on the
front panel (no beep).
The range is 1 Vdc (with a 1 mA current source output).
The voltage is displayed on the front panel if it is in the 0 to 1.2 volt
range. The meter beeps when the signal transitions to the 0.3 to 0.8 volt
threshold (unless beep is disabled). If the signal is greater than 1.2 volts,
"OPEN" is displayed on the front panel.