Storage; Trouble Shooting - Amcor PVMB 12KEH-410 Instruction Manual

Hide thumbs Also See for PVMB 12KEH-410:
Table of Contents

Advertisement

STORAGE

• Empty the internal water container.
• Clean the screen filter.
• Remove the active carbon filter before end of season
storage and install new filters at the beginning of the new
season.
• The old filters can be disposed of in the 'Non-biological
rubbish container'.
Replacement filter packages are available from Amcor.
• Put the unit in Fan Only mode for a few hours to ensure
that the inside becomes completely dry.
• Store the cable as shown.
Protect the unit against dust and store in a dry place, not accessible to children.

TROUBLE SHOOTING

Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty
and can endanger the user and the property.
Problem
The air
No power supply.
conditioner does
Is the LCD light fl ashing.
not function.
Timer function is active.
The air
In direct sunlight.
conditioner does
Windows or doors open, many
not seem to
people or a heat source in the room.
perform.
Dirty filter.
Air inlet or air outlet blocked.
Room temperature lower than the
selected value.
The unit is noisy. Unit stands uneven.
The compressor
The overheat protection is probably
does not work.
activated.
The remote
Distance too great.
control does not
Remote control signal not detected
function.
by the control panel.
The batteries are drained.
To correct problems that have not been described in the table and/or if the recommended solutions fail
to solve the problem, contact an authorized service centre.
Cause
Connect to a functioning outlet and switch on.
Empty the internal water container.
Deactivate TIMER function.
Close curtains.
Close doors and windows, place an extra air
conditioner.
Clean or replace the fi lter(s).
Remove the blockage.
Change temperature selection.
Place on an even, solid surface (less
vibrations).
Wait 3 minutes until the temperature has
decreased, then turn on the unit again.
Make sure the remote control is correctly
aimed at the control panel.
Replace the batteries.
Solution
GB
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pvmb 15keh-410Pvmb 9keh-410

Table of Contents