Always unplug the unit from the wall before performing any maintenance.
Make sure the unit is drained before moving.

Cleaning the Unit:

• Only use a soft damp cloth.
• Never use chemicals, oil-based products, detergents, or other cleaning solutions.
These could damage the cabinet.
Cleaning the "Upper" Filter:
• Slide out the filter holder
from the unit.
• Separate the filter fixer from
the filter holder (see fig. 1).
• Remove the active carbon filter (black) and slide out the 3M™ High Air Flow filter (white).
• To clean filters, vacuum with standard vacuum cleaner.
• Insert the active carbon filter into the filter holder (see fig. 2).
• Insert the 3M™ High Air Flow filter into the filter holder (see fig. 3).
• Fix the filters by reassembling the fixer into the filter holder (see fig. 4).
Cleaning the "Lower" Filter:
• Vacuum with standard vacuum cleaner.
NOTE:
• Before storage be sure filters are clean and dry.
• Should you need to replace filters, contact Amcor for replacement.
• The screen filter must always be used.
• The 3M™ High Air Flow filter should be cleaned periodically. Both filters can be vacuumed.
IMPORTANT: NEVER operate the unit without a filter.

End of Season Storage:

• Unplug the unit.
• Drain the condensed water COMPLETELY.
• Clean the upper and lower filter.