INSTALLING THE OPERATOR
STEP
7:
Install a Rough Service
maximum) firmly in the light socket. Light bulbs in Door Openers are
subject to vibration during normal operation which may shorten their
life spans. Rough Service bulbs, available at most hardware stores,
are recommended.
108385
WARNING
STEP 9: Connecting The Electrical Power
panel of the Opener to determine its proper working voltage. Normally it will be
marked for 115V, 60 cycle operation. (If it is a 230V model the label will clearly
Permanent Wiring Connection
Use an appropriate
conduit connector
Ground Wire &
Chassis Connection
lamp bulb (75 Watt
UNAUTHORIZED OPERATION OF THE DOOR
CONTROLS RISKS INJURY OR DEATH . DO NOT
ALLOW ANYONE UNFAMILIAR WITH THE DOOR
OPERATION TO OPERATE
CONTROLS. MOUNT THE PUSHBUTTON AT
LEAST 5 FT FROM THE FLOOR.
L1 & L2
Connections
110442
STEP 8: Connect the standard wall Push Button
provided to Terminals 1 & 0
panel using a length of 2-conductor, minimum 22 gauge
wire. For mounting the standard Push Button, select a
convenient location near an access door.
LEAST
DISCOURAGE UNAUTHORIZED OPERATION OF
THE DOOR. Install the push button warning label (as
shown below) supplied with the Opener near this
installation.
If you are installing a Deluxe Wall Push Button), See
Page 19 for the proper wiring procedure.
ANY
DOOR
Consult the label on the rear
indicate this.) The Opener
must
be
permanently
wired with a proper
ground
connection
according
to
applicable local, state,
and federal building and
electrical codes.
Run a
three
(3)
conductor
(minimum #14, copper
conductors only) wire from a 15 AMP circuit breaker to the operator in a
suitable conduit. Use an appropriate connector to secure the conduit to the
operator chassis as shown.
wires (L1 and L2) at the terminal block according to the diagram. Secure the
incoming earth ground to the chassis ground screw as shown .
NOTE: GFI protection is recommended especially on steel door applications.
10
on the Opener's rear
5
FT
FROM
THE
This door is operated by
a limited duty operator.
To prevent the motor
protector from tripping -
Do not exceed 6 door
cycles per hour.
WARNING
IMPROPER WIRING COULD
CAUSE ELECTROCUTION
OR DAMAGE TO CIRCUITRY.
all
FOLLOW LOCAL BUILDING
AND ELECTRICAL CODES.
Connect the incoming line and neutral power
110051-3