Page 1
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at Professional/Custom Panel vikingrange.com Built-In Full Height Wine Cellar F20904A EN (101212)
Table of Contents IMPORTANT–Please Read and Follow! • Make sure that incoming voltage is the same Your safety and the safety of others is Warnings & Important Information_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 as unit rating.
Page 3
HAZARD Appliance is top heavy • Viking Range Corporation will NOT warranty any problems resulting from GFI outlets which Disconnect power or turn and tips easily when are not installed properly or do not meet the requirements below.
Dimensions Specifications 30” Professional Description VCWB301/Standard Mount VCWB301/Flush Mount Overall width 30” (76.2 cm) Overall height from bottom 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. ( 7 3 ” . 7 c Overall depth from rear To rear edge of side trim: 22-3/16” (56.4 cm) 23-13/16”...
Cutout Dimensions Cabinet Information (Professional/Custom) (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/16” (5.2 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room. 2”...
Cabinet Information Cabinet Information (Professional) (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/16” (5.2 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room. Wall Wall 1-13/16”...
Page 7
Cabinet Information Cabinet Information (Professional with Flush Mount Trim) (Professional with Flush Mount Trim) Professional models with Flush Mount Trim fit “flush” in standard 24” (61.0 cm) deep cabinet Professional models with Flush Mount Trim fit “flush” in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2”...
Page 8
Cabinet Information Cabinet Information (Custom Panel) (Professional with Flush Mount Trim) Custom Panel models, [3/4” (1.9 cm) thick panels and custom handles locally supplied], fit flush in 25” (63.5 cm) deep (countertop depth) cabinet openings with no protrusion into room except custom handles.
Page 9
Cabinet Information Cabinet Information (Custom Panel) (Custom Panel) Custom Panel models can be installed in standard 24” (61.0 cm) deep openings. However, the Custom Panel models, [3/4” (1.9 cm) thick panels and custom handles locally supplied], fit flush door faces and top ventilation grille will protrude 3/4” (1.9 cm) into the room, ideal for in 25”...
Custom Side Panel Dimensions Custom Side Panel Dimensions (Professional - Standard Mount) (Custom Panel/Professional with Flush Mount Trim) NOTE: Adding a 3/4” (1.9 cm) side TOP VIEW panel adds an additional 3/4” (1.9 TOP VIEW 3/16” 3/4” cm) to the overall width of the product (0.5 cm) (1.9 cm) thick back...
Custom Door Panel Dimensions Door Panel Installation (Custom Panel Model) Panels must not weigh more than 50 pounds per door. 5/16” (0.8 cm) 1-3/8” Pre-drill the holes in the panel per the panel dimension instructions. (See Panel Dimensions for (3.5 cm) proper hole locations.) 11/32”...
Custom Wood Facing Dimensions Custom Wood Facing Dimensions Each wine rack has a wood facing which can be removed. The facings can be stained, painted, or removed and replaced with alternative wood facings. Note: A scrap sample should be tested in the unit before attaching permanent changes to your wine cellar fronts. Some paints and/or stains can cause undesirable odors.
NOTE: Additional mounting boards may IMPORTANT: If the power cord is damaged, be required if the unit does not touch it must be replaced by a Viking qualified the back wall of the enclosure. To technician or a Viking Range Corporation prevent unit from tipping forward, it representative in order to avoid hazard.
Home Security System Connection Securing Your Wine Cellar (3 options) WARNING NOTE: Contact a qualified electrician or authorized agent from alarm company to connect your home security system to the wine cellar. ELECTRICAL SHOCK HAZARD Disconnect power at breaker or turn power Home security system connection must be hooked up before the unit is installed.
Securing Your Wine Cellar Kickplate Installation Before moving the wine cellar in place, confirm the finished dimensions, electrical location, minimum door and shelf clearances, and door panel instructions. The kickplate consists of a two (2) part assembly: one top louvered panel and one bottom solid panel.
Performance Checklist Door Stop/Hinge Adjustment DOOR STOP • Verify cabinet size. Installer’s information: 1. Using a 3/16” Allen wrench, remove door stop pin located in bottom hinge. 2. The pin is factory set 110°. For 120° swing, move the pin to the utmost forward stop hole. •...
• Name of dealer from whom purchased Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range Corporation at (888) 845-4641 or write to:...