Download Print this page

Wire Connection - Kenmore 9410 - 30 in. Electric Range Installation Instructions Manual

30" electric range for 3 or 4 wire, 60hz systems
Hide thumbs Also See for 9410 - 30 in. Electric Range:

Advertisement

4A. Wiring
Instructions
(3-Wire
Connection)
1. Remove the three (3) loose nuts on the terminal block
using a 3/8" nut driver or socket.
NOTE: Do not loosen the nuts which secure the factory
installed range wiring to the terminal block. Electrical
failure or loss of electrical connection may occur if nuts
are loosened.
2.
Using the nuts removed in step 1, connect the cable or
copper power supply cord to the three (3) studs on the
terminal block, as local codes require. The neutral (white)
wire or center wire must be connected to the center
terminal.
3.
Make sure all nuts are tightened securely.
4.
Replace the rear access cover.
GROUNDING
INSTRUCTIONS:
A ground link is installed on this range which connects the
center terminal of the terminal block (neutral) to the chassis.
The ground link is not visible in the picture below but is
connected to the range by the center, lowest screw (shown in
picture below). The ground link must not be removed unless
national or local codes do not permit use of ground link.
NOTE:
If the ground link is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
3-Wire
Connection
4B. Wiring
Instructions
(4-Wire
Connection)
Ifconnectingto a 4-wire electricalsystem (new branch-circuit
or mobile home requires 4 wire connection):
1.
Remove the three (3) loose nuts on the terminal block
usinga 3/8" nut driveror socket. Fromthe center studon
the terminalblock, removethe secondnutand the copper
groundstrap. Replace the nut that held the ground strap
to the terminal block.
NOTE: Do not loosenthe second nut on line 1 or line 2
which secure the factory installed range wiring to the
terminal block. Electrical failure or loss of electrical
connection may occur if nuts are loosened.
2.
Remove the ground screw to release the copper ground
strap from the appliance.
3.
Discard the ground strap. Connect the ground wire
(green) of the copper power supply cordto the frame of
the appliancewiththegroundscrew, usingthe same hole
in the frame where the ground strap was removed.
4.
Using the nuts removed in step 1, connect the neutral
(white) wire ofthe copper powersupplycordtothecenter
silver colored stud on the terminal block.
5.
Connect the final two (2) wires to the outer studs on the
terminal block.
6.
Make sure all nuts are tightened securely.
7.
Replace the rear access cover.
4-Wire
Connection
Terminal
CoJore,
Terminal
\
3-Wire
Copper
Power Supply Cord.
To Fused Disconnect
Box or Approved
Wiring
Device for Copper
Supply Cord.
4-Wire
Copper Power Supply Cord.
To Fused Disconnect
Box or Approved
Wiring Device for Copper
Supply Cord.
40. 8 Green
Insulated
Copper
Ground
Wire

Advertisement