600 mm
600 mm
> 850 mm
THE LOAD DOOR REVERSAL
The load door can be installed by the user
in the opposite side. It can help to easily
put and remove the laundry or if there is a
limit to install the appliance. (see separate
leaflet).

ELECTRICAL CONNECTION

• Connect the appliance to a grounded
socket. Refer to the applicable electri-
cal requirements.
• Make sure that the electrical data on
the rating plate agrees with the power
supply.
• Always use a correctly installed shock-
proof socket.
• Do not use multiple plugs and exten-
sion cables. There is a risk of fire.
• All replacements of power supply cable
must be carried out by our Service.
• Make sure not to squash or cause dam-
age to the mains plug and cable be-
hind the appliance.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The plug must be dry.
The data about mains voltage, type of
current and the necessary fuse are on the
rating plate and in the "TECHNICAL IN-
FORMATION" chapter. The rating plate is
behind the load door (see the "PRODUCT
DESCRIPTION" chapter).
The appliance has a power supply cable
with plug fitted with 13 A fuse. If necessa-
ry, replace the fuse in the plug by 13 A
ASTA BS 1363/A approved fuse.
The wires in the power supply cable are
coloured as follow:
A)
green and yellow - ground — earth (E)
B)
brown - live (L)
C)
cord clamp
D)
blue - neutral (N)
The green and yellow coloured wire must
be connected to the terminal with E mark
or the ground
mark or the green and
yellow coloured terminal.
The blue coloured wire must be connec-
ted to the terminal N or black coloured .
The brown coloured wire must be connec-
ted to the terminal L or red coloured .
The wires of the cable must be no cut or
stray strands of wire present and the cable
clamp must be secure over the outer
sheath.

Permanent connection

The necessary condition of permanent
connection is to install a double-pole iso-
lating switch directly on the supply termi-
nals.
The type of switch must be correct for the
necessary load and must align with appli-
cable electrical requirements.
The switch must not break the yellow and
green coloured ground wire.
ENGLISH