Electrical Requirements; Cabinet Dimensions; Minimum Installation Clearances - KitchenAid KBHS109BSS Installation Manual

27" (68.6 cm) and 30" (76.2 cm) electric built-in convection microwave oven
Hide thumbs Also See for KBHS109BSS:
Table of Contents

Advertisement

Available languages

Available languages

Cabinet Dimensions

27" (68.6 cm) and 30" (76.2 cm) Microwave Ovens
F
E
27" (68.6 cm) models
A. 27" (68.6 cm) min. cabinet
width
B. 18 " (47.3cm) from bottom of
cutout to bottom of upper
cabinet door
C.
" (101.6 cm) bottom of
cutout to floor (recommended)
D. 25 " (64.8 cm) cutout width
E. 1 " (3.8 cm) min. bottom of
cutout to top of cabinet door
F. 17 " (44.7 cm) recommended
cutout height (will fit cutout
height from 17 " [44.1 cm] to
17 " [45.1 cm])
G. 21 " (55.5 cm) min. cutout
depth

Minimum Installation Clearances

For proper installation, the following minimum clearances must
exist above and below the cabinet opening.
Installation Above Single Built-In Oven
A
B
A. Upper cabinet
B. Lower single oven
Approved models: KEBK171B, KEBK101B, KEBS179B,
KEBS109B and KEBU109B.
A
D
B
G
C
30" (76.2 cm) models
A.
" (76.2 cm) min. cabinet
width
B. 18 " (47.3cm) from bottom of
cutout to bottom of upper
cabinet door
C.
" (101.6 cm) bottom of
cutout to floor (recommended)
D. 28 " (72.4 cm) cutout width
E. 1 " (3.8 cm) min. bottom of
cutout to top of cabinet door
F. 17 " (44.7 cm) recommended
cutout height (will fit cutout
height from 17 " [44.1 cm] to
17 " [45.1 cm])
G. 21 " (55.5 cm) min. cutout
depth
1"
(2.5 cm)
1"
(2.5 cm)
from top
of oven

Electrical Requirements

GROUNDING INSTRUCTIONS
For a permanently connected microwave oven:
The microwave oven must be connected to a grounded,
metallic, permanent wiring system, or an equipment
grounding conductor should be run with the circuit
conductors and connected to the equipment grounding
terminal or lead on the microwave oven.
SAVE THESE INSTRUCTIONS
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
microwave oven is properly grounded.
This microwave oven must be connected to a grounded metal,
permanent wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and
all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your microwave oven, you must determine the
type of electrical connection you will be using and follow the
instructions provided for it here.
Microwave oven must be connected to the proper electrical
voltage and frequency as specified on the model/serial
number rating plate. The model/serial number rating plate is
located underneath the control panel, along the oven vent.
A. Model/serial number plate
The microwave oven rated 120/240 volt, 20-amp, has 4 wires
(L1, L2, N and G) in the flex conduit and should be connected
to a 20-amp maximum rated circuit, overcurrent protected on
both the L1 and L2 circuits.
A time-delay fuse or circuit breaker is recommended.
Flexible cable from the microwave oven should be connected
directly to the junction box.
Do not cut the conduit. The length of conduit provided is for
serviceability of the microwave oven.
A UL listed or CSA approved conduit connector must be
provided.
A
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kbhs179bss

Table of Contents