Appendix B
Transceiver, Chassis Connectors, and Cable and Adapter Specifications
Table B-12
Table B-12
SFP+ Transceiver Module Optical Transmit and Receive Specifications
SFP+ Transceiver
Transceiver Type
Module Model
SFP-10G-SR
10GBASE-SR,
850-nm MMF
SFP-10G-LR
10GBASE-LR,
1310-nm SMF
SFP-10G-LRM
10GBASE-LRM,
1310-nm MMF and
SMF
Table B-13
Table B-13
Item
Dimensions (H x W x D)
Operating temperature
Storage temperature
Console Port
Both the Catalyst 4948E and the Catalyst 4948E-F switches can be accessed through a serial console
port located on the chassis front panel. The console port is 10/100/1000BASE-T port that uses an RJ-45
connector. The console port allows you to access the switch either locally (with a console terminal or
PC) or remotely (with a modem).
Table B-14
Table B-14
Pin
1
2
3
4
5
6
7
8
OL-21561-02
lists the SFP+ transceiver optical transmit and receive specifications.
Transmit
Power (dBm)
–1.3 (Max)
–7.3 (Min)
0.5 (Max)
–8.2 (Min)
0.5 (Max)
–6.5 (Min)
lists the physical and environmental specifications for the 10-GB SFP+ transceivers.
10-GB SFP+ Transceiver Physical and Environmental Specifications
lists the console port pinouts.
Console Port Pinouts
Signal
Direction
RTS
output
DTR
output
TXD
output
GND
—
GND
—
RXD
input
DSR
input
CTS
input
Receive Power (dBm)
–1.0 (Max)
–9.9 (Min)
0.5 (Max)
–14.4 (Min)
0.5 (Max)
–8.4 (Min average)
–6.4 (Min in OMA)
Specification
0.04 x 0.53 x 2.22 in. (8.5 x 13.4 x 56.5 mm)
32° to 122°F (0° to 50°C)
–40° to 185°F (–40° to 85°C)
Description
request to send
data terminal ready
transmit data
—
—
receive data
data set ready
clear to send
Catalyst 4948E an Catalyst 4948E-F Switch Installation Guide
Console Port
Transmit and Receive
Wavelength (nm)
840 to 860
1260 to 1355
1260 to 1355
B-11