Troubleshooting; Programming And Testing - ITI 60-770 - Security SuperBus 2000 4-Zone Output Module Installation Instructions Manual

4-relay output module
Table of Contents

Advertisement

2.
Connect the panel battery(s) and restore panel AC
power. Alphanumeric touchpad displays should come
on. Both the green and red LEDs turn on for one sec-
ond, then the green POWER LED will remain on.
3.
Press 8 for System Menu.
4.
Press 0 for Program Menu.
5.
Enter your Install Code (default 0123).
6.
Enter Item Number 48001 to add SuperBus 2000
devices. All installed devices are automatically added
(learned) into panel memory when Devices Added is
indicated.
7.
Press * twice to return to the Main Menu.
8.
The red BUS status LED should flash to indicate suc-
cessful communication with the panel.
Note
If the green POWER LED is not on or the red BUS
status LED does not flash, remove AC panel power,
disconnect the battery(s), and see Table 6 "Trouble-
shooting."
UltraGard Panels
1.
Verify that all wiring at the panel and the module is
correct.
2.
Verify nonconflicting bus unit number settings.
3.
Connect the panel battery and restore panel AC power.
4.
Turn on the panel AC power.
5.
Set the
UltraGard
panel RUN/PROGRAM switch to
PROGRAM.
If the alphanumeric touchpad displays 1-OFF and the 1 is
flashing, you must enter the 4-digit installer access code to
get the panel into program mode.
Alphanumeric touchpads should display PROGRAM
MODE and the red BUS status LED on the module should
be flashing continuously, indicating successful communica-
tion to the panel.
Note
If the green POWER LED is not on or the red BUS
status LED does not flash, set the RUN/PROGRAM
switch (UltraGard) to RUN, remove AC panel power,
disconnect the backup battery, and see Table 6 "Trou-
bleshooting."

Programming and Testing

Refer to the specific panel Installation Instructions for
configuring module outputs, adding (learning) hardwire
sensors, and testing.
SuperBus® 2000 4-Relay Output Module

Troubleshooting

Use the following table to determine possible solutions to
module problems.
Table 6: Troubleshooting
Problem
The green POWER
1.
Check for incorrect wiring con-
LED stays off.
nections.
2.
Make sure panel AC power is
applied and the backup battery(s)
are connected.
3.
If the LED still remains off,
replace the module.
The red BUS LED
1.
Verify that the panel recognizes
doesn't flash to
the module by entering program
indicate
mode (see specific panel Installa-
communication
tion Instructions).
with the panel.
2.
Check for incorrect wiring con-
nections.
3.
For Concord (software versions
1.0–1.6) and UltraGard panels
make sure that module DIP switch
1 is set to "M." For Concord (soft-
ware versions 2.0 or later) and
Advent panels make sure that
module DIP switch 1 is set to "A."
4.
If the LED still doesn't flash,
replace the module.
Output(s) activate
1.
For Concord (software versions
only momentarily,
1.0–1.6) and UltraGard systems,
activate randomly,
check for bus devices with the
or module and/or
same unit number setting.
touchpads lock up.
2.
Re-initialize the panel by discon-
necting and reconnecting panel
power.
3.
Verify that the output/point is con-
figured correctly (see specific
panel Installation Instructions).
4.
Make sure the zone has been
"learned" into panel memory.
5.
Verify that the panel recognizes
the module by entering program
mode (see specific panel Installa-
tion Instructions).
6.
Check module/panel wire routing
and length.
7.
Replace the module.
Module Zone input
1.
Some panels and panel versions
is inoperable.
do not read the module built-in
(UltraGard &
zone input status. Use a panel zone
Concord)
input instead.
One output stays
1.
Check if the point is programmed
activated.
for a 3 minute "on" time and if the
triggering event for the point is
repeatedly "resetting" the 3
minute timer (see specific panel
Installation Instructions).
2.
Output may have failed or been
overloaded. Reprogram using a
different (unused) module output
or replace the module.
Programming and Testing