Installation Guidelines

Installation Guidelines
For the maximum number of bus devices and
touchpads per panel see Table 2.
Table 2: Maximum Bus Devices Per Panel
Panel
Advent
UltraGard
Concord
(software versions 2.0 and later)
Concord
(software versions 1.0–1.6)
Do not exceed the panel total DC output power rating
when using panel power for bus devices and hardwired
detectors (see specific panel Installation Instructions).
Do not exceed the maximum wire length from the
panel to the module (see Table 3).
Table 3: Maximum Wire Lengths
Panel
Advent
UltraGard
Concord
When using self or remotely powered devices with an
Advent panel, do not exceed the maximum recom-
mended wire length of 4000 feet using 22-gauge or
larger wire.
Maximum module current draw with all outputs ener-
gized is 180 mA. Each module draws 12 mA typical
when outputs are not energized (idle).
Do not exceed the module output relay contact ratings
(
4A @ 24VDC, 4A @ 24VAC, 1A @ 70VAC maximum)

Tools and Supplies Needed

Screwdrivers
Drill with bits
Wire cutters/strippers
3/8-inch #6-32 self-tapping screws (included)
22-gauge or larger stranded wire (18-gauge or larger
for commercial applications)
1/4-inch press-fit reed switch and magnet (not
included) for cover tamper
1/4-inch #6-32 self tapping screws (not included) for
Advent cabinet mounting
Support standoff (included with Concord cabinet)
2
Maximum Bus
Devices
62
8
16
16
(up to eight 4-Relay
Output modules)
Maximum Wire Length
22 ga. 200 ft./18 ga. 500 ft.
22 ga. 500 ft./18 ga. 1000 ft.
22 ga. 350 ft./18 ga. 900 ft.
.
Installation
The relay output module can be mounted:
On a wall.
Inside an Advent cabinet.
Inside a Concord cabinet.
Inside a SuperBus Module cabinet (60-698). Refer to
the cabinet Installation Instructions for installation
procedures.
CAUTION
To prevent damaging the panel or card, disconnect the
panel AC Power and backup battery(s) before
installation.
CAUTION
You must be free of all static electricity when handling
electronic components. Touch a bare metal surface
before touching the circuit board.

Mounting the Module

Note
If connecting the module to an UltraGard panel it must
be mounted on a wall. The module will not fit in the
UltraGard cabinet.
Mounting the Module on a Wall
1.
Remove the module cover and set it aside (Figure 2).
PRESS DOWN
HERE AND PULL
AWAY FROM BASE
Figure 2. Removing the Cover
2.
Place the back-plate on the wall and mark the mount-
ing holes (Figure 3).
3.
Drill holes and insert appropriate anchors.
4.
Secure the back-plate to the wall with included
screws.
SuperBus® 2000 4-Relay Output Module