HP StorageWorks 7110 - Virtual Array Manual page 3

Va virtual front panel commands - hp15 firmware release
Hide thumbs Also See for StorageWorks 7110 - Virtual Array:

Advertisement

mgr
-s {shut | start}
-R {full | partial}
-L <loop id> -c {1|2}
-t {1 | 2 | 4} –c {1|2}
-S {1 | 2} –c {1 | 2}
-os {hpux | nt | win2k | linux | solaris | aix | netware |
generic | tru64 | openVMS | mpe | solarisCluster} –c {1 | 2}
-B {autoraid | raid1}
-O { on | off }
-q <queue full threshold>
-ds { on | off }
-p {on | off }
-V <Revision>
fmt
No options
-s: Shutdown or restart the disk array
-R: Reset the disk array
-L: Set the FC Port Loop ID for the
Controller Port.
-t: Set the topology for the Controller
Port. Valid Arguments:
1 - Private Topology
2 - Public Topology
4 - Direct Fabric Attached Topology.
-S: Set the FC Port Speed for the
Controller Port.
Valid Arguments:
1 - 1 GBit/sec Data Rate
2 - 2 GBit/sec Data Rate
-c: Controller for which the port speed
will be set.
-os: Set Host behavior for controller
specified.
-c: Controller for which the host
behavior will be set.
-B: sets array RAID level (AutoRaid |
RAID 1).
-O: set enable optimize policy on/off.
-q: set queue full threshold ( 0 to 4096)
-ds: set disable secondary path
presentation
The -ds option determines whether the
array makes the non-optimal path to
LUNs visible to hosts. When set to ON,
secondary path presentation is enabled
and all LUNs are "visible" through all
ports on all controllers. When set to
OFF, each LUN will be "visible" only on
the controller that is the optimal
controller for that LUN. The optimal
controller is the one associated with the
redundancy group of which the LUN is a
part.
-p: Enable/disable prefetch.
-V: Set volume set revision. Valid
arguments:
1 – For HP01, HP02, HP11, HP13
2 – For HP14, HP15 and greater
Perform array format (will destroy all
user data). User will be prompted with a
yes/no. The word 'yes' must be
entered completely. Otherwise the
format command will be canceled.

Advertisement