Advertisement

Error code
Error message
2831
Cannot change array spare.
2832
Invalid physical drive.
2833
Invalid spare.
2834
Invalid logical drive.
2835
Logical drive not specified.
2836
New logical drive ID does not match the
next available logical drive ID.
2837
New logical drive ID already exists.
2838
Cannot create logical drive.
2839
Cannot migrate logical drive RAID.
2840
Cannot migrate logical drive stripe size.
2841
Cannot extend logical drive.
2842
Invalid RAID.
2843
Invalid size.
2844
Invalid stripe size.
2845
Invalid sectors.
2846
Cannot change logical drive sectors.
2847
Invalid array accelerator setting.
2848
Cannot change logical drive array
accelerator setting.
2849
Invalid ClearConfigurationWithDataLoss
parameter.
2850
Controller does not support RAID Array ID.
Comment or clarification
This error message appears if you try to change the number
of spares in an array when the configuration does not support
the addition or subtraction of spares.
A specified physical drive is not a valid physical drive, or it
cannot be placed in the array.
A specified spare is not a valid spare drive, or it cannot be
placed in the array as a spare.
The script file has commands that require a logical drive, but
no logical drive is specified.
The script file specifies a logical drive ID that is not the first
unused ID in the sequence. For example, this message
appears if the controller has only logical drive 1 and the
script file specifies creation of logical drive 3 (omitting logical
drive 2). A common cause of this error is that the input file
specifies non-sequential logical drive numbers. In this case,
change the logical drive numbers in the input file so that they
are sequential.
This error occurs in Configure mode when the logical drive
ID specified in the script file already exists in the
configuration. In Configure mode, you can create only new
logical drives.
The array has no free space, or the maximum number of
logical drives has already been reached.
The controller does not support RAID migration, or migration
is not possible with the current controller configuration.
The controller does not support stripe size migration, or
migration is not possible with the current controller
configuration.
The controller does not support extension, or the current
controller configuration cannot be extended. For example,
extension is not possible if the array has no free space.
The specified RAID level is invalid or is not possible with the
current configuration.
The specified size is invalid or is not possible with the current
configuration.
The specified stripe size is invalid, or not supported by the
current RAID level, or not possible with the current
configuration.
The specified MaxBoot setting is invalid or is not possible
with the current configuration.
You cannot change the MaxBoot setting on a configured
logical drive because doing so causes data loss.
The specified array accelerator setting is invalid or is not
supported by the current configuration.
You cannot change the array accelerator setting for the
current controller configuration.
Using HPACUSCRIPTING