Technical Support - HP StorageWorks 2/16 - SAN Switch Release Note

Hp storageworks fabric os v3.2.1 release notes (aa-ruqyf-te, january 2006)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Table 1
Issues resolved in this 3.2.1 release (continued)
Issue prior to Fabric OS 3.2.1
Short burst of bad primitives on the link
causes rx_under flow error.
If two or more ports zoned together on a
SAN Switch 2/16, ZONEGROUPADDFAIL
message displayed.
Email configured via Fabric Watch was
not received on certain third party mail
servers.

Technical support

Contact Hewlett-Packard support for hardware, firmware, and software support, including
product repairs and part ordering. To assist your support representative and to expedite your
call, have the following information available:
Technical support contact number, if available
Switch model
Switch operating system version
Error messages received
Output from supportshow command
Detailed problem description and specific questions
Description of any troubleshooting steps already performed and results
Switch serial number
The switch serial number and corresponding bar code are provided on the serial number label,
as shown here.
*FT00X0054E9
World Wide Name (WWN)
At the CLI prompt, type the wwn command to display the switch WWN.
Fix
Fabric OS 3.2.1 extends switch tolerance to the
number of bad primitives.
Multiple ports in same Zone function normally.
Email header format adjusted.
FT00X0054E9
Fabric OS 3.2.1 release notes
5

Advertisement

Table of Contents
loading

Table of Contents