PLV-WF20 Basic Serial Command Functional Specifications
7.10

Status 2 Read Command

COMMAND
"CRA" [CR]
Detail
Get the operating status of Video mute.
Acceptable
Response
Unacceptable
"%1" [CR]
Return a hex digit of 1 byte as two columns of character string.
Define each bit as eight bits by a hex digit as follows.
**** ****
|||| |||└ bit0:Shutter Close = 1 / Open = 0
|||| ||└― bit1:Spare
|||| |└―― bit2:Spare
|||| └――― bit3:Spare
|||└――――― bit4:Spare
||└―――――― bit5:Spare
%1
|└――――――― bit6:Spare
└――――――――bit7:No signal=1, signal=0
ex:
Normal Operation: "00"
Shutter Close: "01"
No signal: "80"
When it is in Standby mode or Cooling Down process, it returns
"FF" even if the status is above.
"?" [CR]