HP P10000 Implementation Manual page 36

Hp 3par hp-ux 11i v2, v3 implementation guide (ql226-96021, august 2011)
Hide thumbs Also See for P10000:
Table of Contents

Advertisement

Recipient Control Flags: 0 Rxsz: 800
Example for Direct Connect
# fcmsutil /dev/fcd0 get remote all
Target Port World Wide Name = 0x20020002ac00003e
Target Node World Wide Name = 0x2ff70002ac00003e
Common Service parameters (all values shown in hex):
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Common Features : 8800 RO_Bitmap: fe
Total Conseq: ff
Class 3 Service parameters (all values shown in hex):
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
Open Sequences/Exchg: 1 Conseq: ff
Recipient Control Flags: 0 Rxsz: 800
1 1. To find the storage volume serial number for the corresponding disk id on the HP-UX host, use
the cstm command. The HP Online diagnostic tool must be installed to access the cstm
command. For example:
# cstm
# selclass type disk
# info
# infolog
. . .
Hardware path: 0/2/0/0.8.0.0.0.0.4
The selected device is not supported by this tool.
Inaccurate information could be displayed by the tool.
Product Id:
Device Type:
Device Qualifier: 3PARdataVV
Serial Number:
Capacity (M Byte):
Block Size:
Max Block Address:
. . .
Check the ioscan -fun disk for the given hardware path and use the HP 3PAR Storage System
CLI command showvlun -lvw or showvv -d to get the volume name. The data which
matches is in bold font:
# showvlun -lvw -host <hostname>
. . .
Active VLUNs
Lun VVname -----VV_WWN-----
4 hpuxN.0 50002AC0003B003E
4 hpuxN.0 50002AC0003B003E
. . .
12. If an HP 3PAR Storage System node is rebooted or an HP 3PAR Storage System Cluster is
rebooted and the connection type is Direct, performing an ioscan or I/O on any storage
volume connected to the Agilent A6795A, A5158A HBA is required in order to see the host
WWN with the showhost command. This is because the HPUX host driver log's into the
target port only on doing one of the above operations.
36
Allocating Storage for Access by the HP-UX Host
Target N_Port_id is = 0x0000ef
Target Loop_id is = 0
Target state = DSM_UNOPENED
Symbolic Name =
Port Type = NL_PORT
FCP-2 Support = NO
VV
Vendor:
SCSI Disk
Firmware Rev: 0000
Logical Unit: 4
003B003E
4096.00
512
8388607
Host ----Host_WWN---- Port Type
hp 50060B0000101A4C 1:0:3 host
hp 50060B00000670A8 2:1:1 host
3PARdata

Advertisement

Table of Contents
loading

This manual is also suitable for:

3par hp-ux 11i v3

Table of Contents