Lamp Command; Cf_Lampmode Command; Cf_Lampcontrl Command; Cf_Lamplifecontrl Command - Sanyo PLC-XTC50AL Specifications

Expand serial command functional specifications
Hide thumbs Also See for PLC-XTC50AL:
Table of Contents

Advertisement

PLC-XTC50AL Expand Serial Command Functional Specifications

8.8 Lamp Command

8.8.1 CF_LAMPMODE Command

Command
"CF_LAMPMODE_%1" [CR]
"AUTO1" ------------- Set lamp status to Auto1 mode
"AUTO2" ------------- Set lamp status to Auto2 mode
"HIGH" --------------- Set lamp status to High mode
"NORMAL" ---------- Set Lamp status to Normal mode
%1
"ECO1" --------------- Set Lamp status to Eco1 mode
"ECO2" --------------- Set Lamp status to Eco2 mode
"UP" ------------------ Select lamp control forward direction
"DN" ----------------- Select lamp control backward direction
Select Lamp control (Available only in the normal Power ON status)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.8.2 CF_LAMPCONTRL Command

Command
"CF_LAMPCONTROL_%1" [CR]
"LAMP1" --------------------------- Set lamp mode to Lamp1
%1
"LAMP2" --------------------------- Set lamp mode to Lamp2
"CHANGE"------------------------- Set lamp mode to Lamp1/2
Select Lamp mode. (Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.8.3 CF_LAMPLIFECONTRL Command

Command
"CF_LAMPLIFECONTROL_%1" [CR]
"MODE1" --------------------------- Set lamp life control to Mode1
%1
"MODE2" --------------------------- Set lamp life control to Mode2
Select Lamp life control (Valid only when in the normal Power ON status.)
Details
The value set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable

8.8.4 CF_LAMPCHGTIM Command

Command
"CF_LAMPCHGTIM_%1" [CR]
"ON" --------------------------- Set Timer to On
%1
"OFF" -------------------------- Set Timer to Off
Select Timer for Lamp1/2 of Lamp mode.
Details
(Valid only when in the normal Power ON status.)
*When Lamp mode is not set to Lamp1/2, error code "101" is returned.
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
34/76

Advertisement

Table of Contents
loading

Table of Contents