System Status 1 LED
Green Blinking

Fan LED

Fan LED
Off
Green Blinking
Green Solid
Amber Solid
Amber Blinking

Temperature Status LED

Temperature LED
Off
Green Solid
Amber Solid
Amber Blinking
Summit WM3400 Wireless LAN Controller Installation Guide
System Status 2 LED
Alternating Green
Blinking & Amber
Blinking
Event
System Off / POST Start
POST in Process
All System Fans Normal Operation
Redundant Cooling Failure
System Operational
System Cooling Failure
System will be held in reset until the issue
is resolved
Event
System Off
Ambient Inlet Temperature is within
specified operating limit
Ambient Inlet Temperature is near the
maximum operating temperature
During controller start up this LED will be
lit Solid Amber. This is normal behavior
and does not indicate an error.
Ambient Inlet Temperature is above the
maximum specified operating temperature
System will be held in reset until the issue
is resolved
Event
Redundant System not failed over.