POST (Power On Self Test) Error Messages
The Integrated Administrator (IA) has details containing new information it receives from the Blade
Management Controller (BMC). You can use the IA syslog to determine when a fault occurred.
Message
101-Option ROM Checksum Error
102/103-System Board error
162-System Options Not Set
163-Time & Date Not Set
164-Memory Size Error
201-Memory Error
301-Keyboard Error
303-Keyboard Controller Error
304-Keyboard or System Unit Error
1780-Disk 0 Failure
1792-No IDE fixed disk present
Health LED
Corrective Action
●
Red
Clear CMOS.
●
Flash ROM if necessary.
●
Replace blade PC.
Red
●
Clear CMOS.
●
Replace blade PC.
Amber
●
Set time and date in Computer Setup.
●
Replace RTC battery.
Amber
●
Set time and date in Computer Setup.
●
Replace RTC battery.
Amber
●
Ensure DIMMs properly installed.
●
Verify proper DIMM type.
●
Remove and replace modules one at a time to isolate
faulty module.
●
Replace blade PC.
●
Red
Ensure DIMMs properly installed.
●
Verify proper DIMM type.
●
Remove and replace modules one at a time to isolate
faulty module.
●
Replace blade PC.
●
Amber
Reconnect keyboard with blade PC turned off.
●
Try different keyboard.
●
Replace blade PC.
Amber
●
Reconnect keyboard with blade PC turned off.
●
Replace keyboard.
●
Replace blade PC.
●
Amber
Run Computer Setup DPS Self Test from Computer
Setup.
●
Replace hard drive.
●
Amber
Check if hard drive is present. If so, run Computer
Setup DPS Self Test from Computer Setup.
●
Replace hard drive.
POST (Power On Self Test) Error Messages