1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the Rack Installation Instructions that comes with the server.
3. Remove the server cover. See "Removing the server cover" on page 69.
4. Remove the cooling shroud. See "Removing and reinstalling the cooling shroud" on page 73.
5. Locate the riser card assembly 1. See "Server components" on page 22.
6. Grasp the riser card assembly 1 by its edges and carefully lift it straight up and off the chassis.
Figure 95. Lifting the riser card assembly 1 off the chassis
7. If there is any PCI Express card (such as an Ethernet card) installed on the riser card assembly 1, note
down the cable connections, disconnect all cables from the card, and then completely remove the riser
card assembly 1 out of the chassis. Then, remove the PCI Express card from the riser card assembly 1.
See "Removing the Ethernet card" on page 83.
8. Touch the static-protective package that contains the new riser card assembly 1 to any unpainted
surface on the outside of the server. Then, take the new riser card assembly 1 out of the package.
144
ThinkServer RD330 Hardware Maintenance Manual