PLC-HF10000L Basic Serial Command Functional Specifications
7.7

Temp Read Command

COMMAND
"CR6" [CR]
Get the temperature information inside projector
Detail
With more than one temperature sensors installed in the projector, it is possible
to get all temperatures at once.
Acceptable
Response
%10 %2
Unacceptable
7.8

Lamp Mode Read Command

COMMAND
"CR7" [CR]
Get current Lamp Mode in the multiple-lamp projector.
Detail
When there is any fail lamp, also can get the information about.
Acceptable
Response
Unacceptable
"%1ÿ ? %2" [CR]
%1 = temperature at Sensor 1
%2 = temperature at Sensor 2
Temperature data is expressed as "00.0".
When the temperature goes under 0, the first character is "-" like
"-05.5" [CR].
When no temperature data returns due to hardware problems
the first character is "E" like" E00.0" [CR].
With more than one temperature sensors installed, the projector
returns the values in series.
Ex) "_31.5_ _35.2" [CR]
Each sensor data follows in sequence with one space between
each of them.
"?" [CR]
"%1" [CR]
ex: "0F"[CR]
The first digit indicates Lamp Mode.
0 = 2lamp Mode
1 = 1lamp Mode (Lamp No.1 used)
2 = 1lamp Mode (Lamp No.2 used)
%1
The second digit indicates if the lamp is ON or OFF.
Data is shown as "0-9" and "A-F", which is described in 4-bit
data. Assign each bit for each lamp data.
ex: 0 = ALL is OFF
1 = No.1 is ON, the other is OFF
2 = No.2 is ON, the other is OFF
3 = ALL is ON
"?" [CR]
20/23