PLC-HF10000L Basic Serial Command Functional Specifications
6.4
Operation Requirements
When the projector is in the status below, Functional Execution Commands are limited.
(Status Read Commands are available in following status)
Projector Status
In Standby status
Count Down in process
Cooling Down in process
Cooling Down in process due to abnormal
temperature
In Abnormal Temperature
In Abnormal Power Status
On switching modes
Power Saving Cooling Down in process
In Power Saving status
Note) In the above status, it returns [ACK] [CR] even if the projector receives other commands,
6.5
POWER ON Command
COMMAND
"C00" [CR]
Power ON
When already Power is ON, no operation starts.
Detail
When sending this command during Count Down in process, Count Down
process is terminated.
Acceptable
Response
Unacceptable
6.6
POWER OFF Command (Immediate POWER OFF)
COMMAND
"C01" [CR]
Power OFF (Standby)
When Power is turned OFF with ON/STAND-BY button of the projector and
Detail
remote control, "Power OFF" is displayed. In contrast, this command executes
immediately Power OFF.
Acceptable
Response
Unacceptable
6.7
INPUT 1 Command
COMMAND
"C05" [CR]
Select Input 1
Detail
Note) When there is no board inserted to Input 1, it is not executed.
Acceptable
Response
Unacceptable
Available Functional Execution Commands
C00: POWER ON
C00: POWER ON (Countdown is terminated)
NONE (No Execution)
NONE (No Execution)
NONE (No Execution)
NONE (No Execution)
NONE (No Execution)
NONE (No Execution)
C00: POWER ON
C01: POWER OFF
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
8/23