Status Read Command - Sanyo PLC-HF10000L - 10000 Lumens Manual

Basic serial command functional specifications
Hide thumbs Also See for PLC-HF10000L - 10000 Lumens:
Table of Contents

Advertisement

PLC-HF10000L Basic Serial Command Functional Specifications
7.3

Status Read Command

COMMAND
"CR0" [CR]
Detail
Get the projector status
Acceptable
Response
Unacceptable
0 Details for Response0
"00" [CR]
Status: Power ON
Normal image is on screen.
"80" [CR]
Status: Standby
When the status is Standby, Status Read Commands are always accepted, but Functional
Execution Commands are not accepted except POWER ON Command.
"40" [CR]
Status: Countdown in process
When "Display" in Setting menu is set to ON, execution of Power ON operation brings into
Countdown status.
When "Display" in Setting menu is set to OFF, the status jumps to Power ON without
Countdown operation.
"20" [CR]
Status: Cooling Down in process
Execution of POWER OFF Command ("C01" [CR]) in power on status brings into Cooling
Down status.
This status automatically moves to Standby when the lamp is turned off and the fan spin
finishes after about 90 seconds (the time of spinning fan depends on models).
During this time, Functional Execution Commands are not accepted.
"%1" [CR]
"00" = Power ON
"80" = Standby
"40" = Countdown in process
"20" = Cooling Down in process
"10" = Power Failure
"28" = Cooling Down due to Abnormal Temperature in process
"24" = Power Management Cooling Down in process
"04" = Power Management status
%1
"21" = Cooling Down in process after Off due to lamp failure
"81" = Standby after Cooling Down due to lamp failure
"88" = Standby after Cooling Down due to
Abnormal Temperature
"2C" = Cooling Down in process after Power Off due to
Shutter management
"8C" = Standby after Cooling Down due to
Shutter management
"?" [CR]