Lenovo 821532U - ThinkCentre M52 - 8215 Hardware Maintenance Manual page 83

User manual
Table of Contents

Advertisement

Diagnostic Error Code
175-197-XXX
Thermal Sensor(s) test warning
175-198-XXX
Thermal Sensor(s) test aborted
175-199-XXX
Thermal Sensor(s) test failed, cause
unknown
175-250-XXX
175-251-XXX
Thermal Sensor(s) limit error
185-000-XXX
Asset Security Test Passed
185-XXX-XXX
Asset Security failure
185-278-XXX
Asset Security Chassis Intrusion
201-000-XXX
System Memory Test Passed
201-XXX-XXX
System Memory error
202-000-XXX
System Cache Test Passed
202-XXX-XXX
System Cache error
206-000-XXX
Diskette Drive Test Passed
206-XXX-XXX
Diskette Drive error
FRU/Action
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 53
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See "Flash
update procedures" on page 516
3. Go to "Undetermined problems" on page
88
1. See "Undetermined problems" on page
88
2. Flash the system and re-test. See "Flash
update procedures" on page 516
3. Replace component under function test
1. Check fans
2. Check Power supply voltages
3. Microprocessor
4. System board
No action
1. Flash system
2. System board
1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
No action
1. Replace the memory module called out
by the test
2. System board
No action
1. Cache, if removable
2. System board
3. Microprocessor
No action
1. Diskette Drive Cable
2. Check power supply voltages
3. Diskette drive
4. System board
Chapter 7. Symptom-to-FRU Index
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents