Lenovo 821532U - ThinkCentre M52 - 8215 Hardware Maintenance Manual page 71

User manual
Table of Contents

Advertisement

Diagnostic Error Code
006-195-XXX
Diskette interface Test aborted by user
006-196-XXX
Diskette interface test halt, error threshold
exceeded
006-197-XXX
Diskette interface test warning
006-198-XXX
Diskette interface test aborted
006-199-XXX
Diskette interface test failed, cause unknown
006-25X-XXX
Diskette interface Error
011-000-XXX
Serial port Interface Test Passed
011-001-XXX
Serial port Presence
011-002-XXX
011-003-XXX
Serial port Timeout/Parity error
011-013-XXX
011-014-XXX
Serial port Control Signal/Loopback test
failure
011-015-XXX
Serial port External Loopback failure
011-027-XXX
Serial port Configuration/Setup error
011-03X-XXX
011-04X-XXX
Serial port failure
FRU/Action
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. If a component is called out, make sure
it is connected and/or enabled
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test. See "Flash
update procedures" on page 516
3. Go to "Undetermined problems" on page
88
1. Go to "Undetermined problems" on page
88
2. Flash the system and re-test
3. Replace component under function test
1. Diskette drive cable
2. Diskette drive
3. System board
No action
1. Remove external serial device, if
present
2. Run setup, enable port
3. System board
System board
System board
1. Wrap plug
2. System board
1. Run Setup, enable port
2. Flash the system. See "Flash update
procedures" on page 516
3. System board
System board
Chapter 7. Symptom-to-FRU Index
65