LOCATION REQUIREMENTS

You will need:
A location allowing for proper exhaust installation.
See "Venting Requirements."
A separate 15 or 20 amp circuit for a gas dryer or 30 amp
circuit for an electric dryer.
If using power supply cord, a grounded electrical outlet
located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
Floor must support dryer weight of 200 lbs. (90.7 kg).
Also consider weight of companion appliance.
Cold water faucets located within 4 ft. (1.2 m) of the water fill
valves, and water pressure of 20 - 120 psi (138 - 827 kPa).
You may use the water supply for your washer using the "Y"
connector and short hose (if needed) which are provided.
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
For garage installation, place dryer at least 18" (457 mm)
above floor. If using a pedestal, you will need 18" (457 mm)
to bottom of dryer.
The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
IMPORTANT: Do not operate, install, or store dryer where
it will be exposed to water, weather, or at temperatures below
40° F (4° C). Lower temperatures may cause dryer not to
shut off at end of automatic sensor cycles, resulting in longer
drying times.
DRYER DIMENSIONS
Front view:
/
3
35
"
8
(899 mm)
1"*
(25 mm)
* Approx. measurement
Side view:
/
48
3
"
4
(1238 mm)
1"*
(174 mm)
(25 mm)
* Approx. measurement
Back view:
Electric
5
3
/
"*
Vent
4
(146 mm)
Gas
1"
(25 mm)
* Approx.
measurement
NOTE: Most installations require a minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with elbow. See "Venting Requirements."
27"
(686 mm)
29"
(737 mm)
3
5
/
(146 mm)
/
3
1
"
2
(89 mm)
/
/
6
7
"
"
8
/
1
6
"
4
(159 mm)
28
(715 mm)
Vent:
3
1
/
" (89 mm)
Water inlet
2
Water Inlet:
3
1
/
" (83 mm)
4
6
1
/
"*
8
(156 mm)
14"
(358 mm)
Steam models only
25
1
/
"
2
(650 mm)
/
3
35
"
8
(899 mm)
"
4
/
1
"
8
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wgd9371ylWgd9371ywMgde201ywMgde301ygMgde301yw

Table of Contents