Maytag electric dryer dimensions and installation
Hide thumbs Also See for MEDX500X:

Advertisement

PRODUCT MODEL NUMBERS
MEDX500X, MEDX550X, MEDX600X,
MEDX700A, MEDX700X
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Dryer Dimensions
43"
(1092 mm)
*29
/
"
1
2
(749 mm)
27"
(687 mm)
A
A. Large opening side-swing door
B. Wide opening hamper door
Minimum spacing for recessed area or closet installation
18"*
(457 mm)
27"
1"
1"
(686 mm)
(25 mm)
(25 mm)
A
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
Installation spacing for recessed area or closet installation
The dimensions shown below are the recommended spacing for this dryer.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, floor moldings, and dryer venting.
Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise
transfer.
For closet installation, with a door, minimum ventilation openings in the top and bottom of the door
are required. Louvered doors with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
23¾"
(603 mm)
43"
(1092 mm)
*29
/
"
1
2
(749 mm)
14" max.*
2
48 in.
*
(356 mm)
2
(310 cm )
*
2
24 in.
2
(155 cm )
1"*
29
5
¼"
½"*
(25 mm)
(743 mm)
(140 mm)
B

Electric Dryer

13¾"
(349 mm)
27"
*Most installations require a minimum 5½" (140 mm)
(687 mm)
clearance behind the dryer for the exhaust vent with
B
elbow. See "Venting Requirements."
3"*
(76 mm)
3"*
(76 mm)
C
W10115226C
02/2012

Advertisement

loading

Summary of Contents for Maytag MEDX500X

  • Page 1: Electric Dryer

    Electric Dryer PRODUCT MODEL NUMBERS MEDX500X, MEDX550X, MEDX600X, MEDX700A, MEDX700X Installation clearances: The location must be large enough to allow the dryer door to open fully. Dryer Dimensions 23¾" (603 mm) 43" 43" (1092 mm) (1092 mm) 13¾" (349 mm) "...
  • Page 2: Electrical Requirements

    ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.

This manual is also suitable for:

Medx550xMedx600xMedx700aMedx700x