Appendix
Indicators and Projector Condition
Check the indicators for projector condition.
Indicators
WARNING
POWER
red/green
• • • emits green light
✽
When the life of the projection lamp draws to an end, the LAMP REPLACE indicator emits yellow light. In this case, replace the
projection lamp with a new one promptly. Reset the Lamp replacement counter after replacing the lamp. See pages 48 and 49.
54
LAMP
REPLACE
red
yellow
The projector is off. (The AC power cord is unplugged.)
The projector is preparing for stand-by or the projection lamp is being
✽
cooled down. The projector cannot be turned on until cooling is completed.
✽
The projector is ready to be turned on with the POWER ON-OFF button.
✽
The projector is operating normally.
✽
The projector is in Power management mode.
The temperature inside the projector is abnormally high. The projector
cannot be turned on. When the projector is cooled down enough and the
✽
temperature returns to normal, the POWER indicator turns to steady red
and the projector can be turned on. (The WARNING indicator keeps
blinking.) Check and clean the air filters.
The projector has been cooled down enough and the inside temperature
✽
returns to normal. When turning on the projector, the WARNING indicator
stops blinking. Check and clean the air filters.
The projector detects an abnormal condition and cannot be turned on.
Unplug the AC power cord and plug it again to turn on the projector. If the
✽
projector is turned off again, unplug the AC power cord and contact the
dealer or the service center for service and checkup. Do not leave the
projector on. It may cause an electric shock or a fire hazard.
• • • blinks green
Projector Condition
• • • blinks red
• • • emits red light
• • • off