5.3

Interface Signals

5.3.1 Serial Interface Signals

The display is designed to be operated by a standard RS–232 serial interface. The user can operate the
module with any interface which meets the following requirements for a "mark" condition and a "space"
condition. The user should observe generally accepted design rules when interfacing to the display.
Space Voltage (V
Mark Voltage (V
6.0

ENVIRONMENTAL CHARACTERISTICS

6.1

Operating

Temperature:
Humidity: (@ 40ºC)
Humidity ( 40 C):
Vibration:
Shock:
6.2
Non–Operating
Temperature:
7.0

OPTICAL SPECIFICATIONS

7.1

Optical Characteristics

Format:
Character Font:
Character Height w/ cursor:
Character Height w/o cursor:
Character Width:
Overall Active Area:
Peak Vertical Viewing Angle:
Viewing Mode:
Item
Viewing Angle–Vertical
Viewing Angle–Horizontal*
Contrast ratio (Peak)**
Response time (ON)**
Response time (OFF)**
* Measured at peak vertical angle,
** Measured at peak viewing angles:

Industrial Electronic Engineers, Inc.

Van Nuys, California
Data – V
Data RTN)
RX
RX
Data – V
Data RTN)
RX
RX
–30 to +80°C
95% RH (non–condensing)
Absolute humidity must be lower the humidity of 95% RH at 40 C
10g at 10 to 400Hz (3 axes)
10g (all axes)
–40°C to +85°C
Symbol
1– 2
T
CR
t
r
t
f
= –20°
+3.0 to +25.0 Volts
–25.0 to +0.8 Volts
Four lines of 20 characters
5x7 dot matrix with cursor
0.48" (12.1mm)
0.39" (9.9mm)
0.24" (6.1mm)
5.70" x 2.34" (144.9mm x 59.5mm)
20° below normal plane
Reflective, light field
Condition
CR=2.0, =0°
CR=2.0
25°C
25°C
–30°C
25°C
–30°C
SIZE
CODE IDENT NO.
A
05464
SCALE
N/A
REV C
Min
Typ
Max
100
120
±45
±55
10
18
100
150
2000
150
200
4000
S03805–06–0200
SHEET 20
Unit
deg.
deg.
mS
mS
mS
mS

Advertisement