Built-In Clearance Dimensions
Side View
10
VENTILATION FOR BUILT-IN INSTALLATIONS
Vents
5.00 inch
maximum
No more than 5.00 inches above
the floor of the installation.
1. At least one ventilation opening shall be provided on the exposed exterior side of the enclosure located within 5
inches (127 mm) of the top of the enclosure and unobstructed. The opening(s) shall have a total free area of not
less than 1 in
2
/lb (14.2 cm
2
/kg) of stored fuel capacity.
2. At least one ventilation opening shall be provided on the exposed, exterior side of the enclosure 1 inch (25.4 mm)
or less from the floor level and shall have a total free area of not less than 1/2 in
capacity. The upper edge shall be no more than 5 inches (127 mm) above the floor level.
3. Every opening shall have a minimum dimension so as to permit the entrance of a 1/8 inch (3.2 mm) rod.
Not less than
5.00 inches
from inside
bottom of
countertop.
5.00 inch
maximum
1.00 inch maximum
Not less than
1.00 inch from
inside floor of
installation.
2
/lb (7.1 cm
2
/kg) of stored fuel
11