•¡ Turn the dial while pressing the STEP BACK switch to change the values.
SW No.
setting range
memo-30
memo-31
memo-32
memo-33
memo-34
memo-35
memo-36
memo-37
memo-38
memo-39
memo-3A
memo-3b
memo-3c
memo-3d
memo-3E
Possible
Initial
Units
value
10ms
1 999
1 4
1 7
x 7.5
1 10
1 5
ms
10 60
1 3
0 3
0.1s
1 20
0 11
11. Changing special functions using the memory switches
Time until feed mechanism starts moving after work clamp has lifted.
10
Changes the feed speed.
1
1 (Fast)
Changes the possible sewing speed for a given stitch length.
1 (Fast)
1 (2,700/3 mm), 2 (2,600/3 mm), 3 (2,500/3 mm),
4 (2,300/3 mm), 5 (2,000/3 mm), 6 (1,800/3 mm),
3
7 (1,200/3 mm)
Settings 1 and 2 are outside the warranty specification
at the time of shipment from the factory.)
Changes the feed timing
5
1 (Fast)
Number of low-speed stitches sewn at 400 spm at sewing start
0
Solenoid ON time changes when work clamp is being lowered
(solenoid specifications only)
40
10
(Quiet)
The solenoid ON time when the presser foot is raised
changes.
1
(Standard) 1
Specifies the enlargement and reduction method when
reading from a 2DD floppy disk.
0
0: No conversion; 1: 311, 311A; 2: 326, 326A, 326L,
326LA; 3: 341, 341A, 342, 342A
Delay time from the point when the cassette is clamped
to the start of sewing when DIP switch A7 is ON during
1
automatic sewing
Sets the enlargement and reduction home positions on
0
the panel.
0
0
0
0
0
BAS-343E
Explanation
4 (Slow)
7 (Slow)
5 (standard)
10(Slow)
60
(High work clamp capacity)
3 (Upper limit)
49