6-3. Using the program R/W (Read/Write) switch

Programmed stitch patterns stored on floppy disk can be read into memory, and newly programmed patterns can
be written to disk for permanent storage and later recall.
w\
e
r
MENU
X - SCALE
Y - SCALE
SPEED
B. B.T. COUNTER
. COUNTER
PROGRAM NO.
PROGRAM NO.
R / W
STEP BACK
STEP BACK
y
i
Insert the floppy disk q containing or which is to con-
tain the programmed stitch pattern.
To READ a pattern to memory
Press the program select switch e on the operation
panel. The program number will then appear in the
PROGRAM NO. display w. After selecting the desired
program number, press the R/W switch r. The disk
drive indicator t will illuminate and a "P" will appear
on the PROGRAM NO. display w to indicate that the
data is being read. When the alarm sounds and the
disk drive indicator t turns off, the program number
will then flash in the PROGRAM NO. display w instead
of the "P" to indicate that the reading of the data is
complete.
To WRITE a pattern to disk
Press the program select switch e on the operation
panel to select the desired program number. After pro-
gramming the pattern using the stitch programmer,
press the R/W switch r. The disk drive indicator t
will illuminate and a "P." will appear on the PROGRAM
NO. display w to indicate that the data is being writ-
ten. When the alarm sounds and the disk drive indica-
tor t turns off, the program number will then flash in
the PROGRAM NO. display w instead of the "P" to
indicate that the writing of the data is complete.
If an error message is displayed
If an error message code is displayed in the display u,
and alarm will sound.
Press the emergency stop switch y on the front of the
machine to stop sewing machine operation, and then
refer to and follow the error code list on page 59.
Clearing the error
1. Turn the EMERGENCY STOP switch u clockwise and
then pull it forward to release it.
2. Press the STEP BACK switch i on the operation panel
(when memory switch No. 0d is ON).
If memory switch No. 0d is OFF, press the EMER-
GENCY STOP switch u once more to release it.