Installing The Cable-Management Arm - Dell PowerEdge 2950 Installation Manual

Rack installation guide
Hide thumbs Also See for PowerEdge 2950:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
4 Pull the system out of the rack until it stops because of the safety catch.
5 Pull up on the front release latch on each rail to disengage the safety catch (see Figure 1-7) and slide
the system forward.
6 Pull the system completely out of the rack.

Installing the Cable-Management Arm

NOTE:
You can attach the cable-management arm to either side of the rack cabinet.
NOTE:
Attach the cable-management arm ramp assembly to the side opposite of where you attach the cable-
management arm.
1 Fit the latch on the front end of the cable-management arm onto the bracket on the end of the
mounting rail until the latch clicks (see Figure 1-8).
2 Fit the latch on the unattached end of the cable-management arm onto the bracket on the end of the
slide assembly until the latch clicks (see Figure 1-8).
CAUTION:
Both ends of the cable-management arm must be connected before you begin routing the system
cables.
Figure 1-8. Installing the Cable-Management Arm
back of system
1
mounting rails (2)
3
latches (2)
1
2
2
brackets (2)
4
cable-management arm
3
4
Rack Installation Guide
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge 2970

Table of Contents