LV-7575 Basic Serial Command Functional Specifications

6.4 Operation Requirements

In the following status of projector, Available Functional Execution Commands are limited.
Projector Status
Standby Mode
Countdown in process
Cooling Down in process
Cooling Down due to Abnormal
Temperature
Abnormal Temperature Status
Power-Save Cooling Down in process
Power Save Status
Cooling Down in process after OFF
operation due to Lamp Failure
Note) in above status, the projector returns [ACK] [CR] even if it receives the other command.

6.5 POWER ON Command

Command
"C00" [CR]
Power ON
When already Power is ON, no operation is started.
Detail
When sending this command during Countdown in process, Countdown is
terminated.
Acceptable
Response
Unacceptable

6.6 POWER OFF Command (Quick POWER OFF)

Command
"C01" [CR]
Power OFF (Standby)
This command executes Quick Power OFF operation without displaying "Power
Detail
OFF?" message, which is displayed when Power is turned OFF with ON-OFF
button of the projector or remote control.
Acceptable
Response
Unacceptable

6.7 POWER OFF Command

Command
"C02" [CR]
Power OFF (Standby)
This command works the same way as when Power is OFF with ON-OFF button
of the projector and remote control.
(When the command is sent once, "Power OFF?" message is displayed. If this
Detail
command is sent again while "Power OFF?" message is displayed, Power OFF
operation is executed.)
When sending this command during Countdown in process, Countdown is
terminated.
Acceptable
Response
Unacceptable
Available Functional Execution Commands
C00: POWER ON
C00: POWER ON • ¨
C01: POWER OFF
C02: POWER OFF • ¨
C46: ZOOM -
C47: ZOOM +
C4A: FOCUS -
C4B: FOCUS +
C5D: LENS SHIFT +
C5E: LENS SHIFT -
NONE (No Execution)
NONE (No Execution)
NONE (No Execution)
NONE (No Execution)
C00: POWER ON
C01: POWER OFF
NONE (No Execution)
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
[ACK] [CR]
"?" [CR]
11/26
Countdown is terminated
Countdown is terminated

Advertisement