Intel Desktop Board DG35EC Technical Product Specification
1.13.1.2 ENERGY STAR*
In 2007, the US Department of Energy and the US Environmental Protection Agency
revised the ENERGY STAR* requirements. Intel has worked directly with these two
governmental agencies to define the new requirements. Currently this Intel
Board meets the Cat B requirements.
For information about
ENERGY STAR requirements and recommended configurations
1.13.1.3
Wake-up Devices and Events
Table 8 lists the devices or specific events that can wake the computer from specific
states.
Table 8. Wake-up Devices and Events
These devices/events can wake up the computer...
LAN
PME# signal
Power switch
PS/2 devices
RTC alarm
Serial port
USB
WAKE# signal
Note: For LAN and PME# signal, S5 is disabled by default in the BIOS Setup program. Setting this option to
Power On will enable a wake-up event from LAN in the S5 state.
NOTE
The use of these wake-up events from an ACPI state requires an operating system
that provides full ACPI support. In addition, software, drivers, and peripherals must
fully support ACPI wake events.
32
®
Refer to
http://www.intel.com/go/energystar
...from this state
(Note)
S1, S3, S4, S5
(Note)
S1, S3, S4, S5
S1, S3, S4, S5
S1, S3
S3, S4, S5
S3
S3
S1, S3, S4, S5
Desktop