Fabric OS 6.1.0f fixes
Table 12
lists defects closed in this Fabric OS 6.1.0f firmware release.
Table 12 Fabric OS 6.1.0f closed defects
Closed defect summary
A failed Pause frame, sent during firmwaredownload process in
Interop Modes 2 and 3, causes a fabric rebuild
A device with a slow initialization sequence may cause the switch to
mistakenly establish virtual channels on an F_Port.
A CRC error was observed between HP StorageWorks 8/40 SAN
Switch and HP StorageWorks 8/80 SAN Switch with a particular SFP
type.
The Fibre Channel fastwrite path does not recover after restoring the
DWDM connection.
Devices on the backbone have no access to remote devices after a
switch on the backbone, with both FCR and FCIP being utilized, exper-
iences a hafailover or hareboot.
Port RSCNs are sent to DPC (VIs and VTs) every time the configuration
changes, which is unrelated to VI/VT. This affects any application that
uses frame redirect zoning.
With both RD zone and TI zone configured, a connectivity issue can
occur after hafailover or hareboot.
Fabric OS 6.1.0g fixes
Table 13
lists defects closed in the Fabric OS 6.1.0g firmware release.
Table 13 Fabric OS 6.1.0g closed defects
During firmwaredownload, a rare race condition could occur,
causing /etc/inetd.conf to be erased, and leading to the user
being unable to access the switch via the network.
A Web Tools performance issue occurs, where it freezes for a few
seconds approximately every 15 seconds. The Web Tools light stops
blinking and cannot scroll any windows.
28
Closed defect summary
Solution
Fixed in Fabric OS 6.1.0f.
Workaround: Use the
firmwaredownload —o option to
override the uncooperative HCL
feature.
Fixed in Fabric OS 6.1.0f.
Fixed in Fabric OS 6.1.0f.
Fixed in Fabric OS 6.1.0f.
Fixed in Fabric OS 6.1.0f.
Workaround: To recover, disable and
then enable the VEX/EX ports.
Fixed in Fabric OS 6.1.0f.
Fixed in Fabric OS 6.1.0f.
Workaround: Run the efgdisable
and efgenable commands.
Solution
Fixed in Fabric OS 6.1.0g.
Fixed in Fabric OS 6.1.0g.