Symptom
Upgraded firmware from v5.0.x to v5.2.1a. The Brocade 24000 crashed when new firmware went
active.
Probable cause and recommended action
RNID processing enhancement in firmware.
The following message will appear in the switches log:
2007/05/13-07:06:56, [KSWD-1003], 78412/24993, FFDC, WARNING, SilkWorm24000,
kSWD: Detected unexpected termination of:
''[4]ficud:0'RfP=712,RgP=712,DfP=0,died=1,rt=87261,dt=36843,to=50000,aJc=35761,aJ
p=19101,abiJc=1942030008,abiJp=1942013308,aSeq=3,kSeq=0,kJc=0,kJp=0,J=50418,rs=2'
, swd.c, line: 462, comp:ficud, ltime:2038/01/18-20:31:28
This problem occurred due to the RNID-processing enhancement in the Fabric OS code. The
mainframe configuration was sending out a lot of RNIDs to the switch and it could not process all of
them in a timely manner.
To fix this issue upgrade to v5.2.2 or v5.3.0.