PROGRAMMING

KEYPAD PROGRAMMING

PROGRAMMING NUMBER
1
2
7
9
03
04
06
07
09
51
52
53
54
56
021
023
024
025
DIRECT COMMANDS FROM THE UNIT KEYPAD
KEYSTROKES
User Code + 1
User Code + 2
AUDIO FEEDBACK FROM THE UNIT:
1 Low Tone Beep = Failure
2 Two High Tone Beeps = Valid sequence
3 Low Tone Beep = Error or invalid sequence
NOTE: Use the STAR Key "*" to cancel any input.
NOTE: Keypad commands are to be entered in a single string to result in success (indicated by double high tone).
Stop and go keystrokes will result in negative tones (low single and triple fail tones).
» QUICK REFERENCE
DESCRIPTION OF TASK
Trigger Relay One
Trigger Relay Two
Delete User Code
Enter User Code
Enable Intercom (No-Telco) Mode
Enable Telco Mode
Speaker Volume
Microphone Sensitivity
Change the Master Code
Create Temporary (1 Shot) Code
Enable Vacation (Lock Down)
Mode
Disable Vacation (Lock Down)
Mode
Engage Party Mode (Relay 1)
Engage Party Mode (Relay 2)
Enable Parallel Relay Output
Enable Independent Relay Output
Control
Adjust Relay Output Time (Relay 1)
Adjust Relay Output Time (Relay 2)
Triggers Relay 1
Triggers Relay 2
FACTORY SETTING PROGRAMMING PROCEDURE
Master Code (4 digits) + 1
Master Code (4 digits) + 2
Master Code (4 digits) + 7 + User Code that is to be deleted
(4 digits)
Master Code (4 digits) + 9 + New User Code
(4 digits) + Relay Associated with the User Code (1 or 2)
Master Code (4 digits) + 03
Enabled
Master Code (4 digits) + 04
Master Code (4 digits) + 06 + Volume Level
Level 2
(1 = Low, 2 = Medium or 3 = High)
Master Code (4 digits) + 07 + Volume Level
Level 2
(1 = Low, 2 = Medium or 3 = High)
Master Code (4 digits) + 09 + ### + New Master Code
(4 digits)
Master Code (4 digits) + 51 + New Temporary (1 Shot) Code
(4 digits) + Relay Associated with the User Code (1 or 2)
(Expires after 24 hours)
Disabled
Master Code (4 digits) + 52
Master Code (4 digits) + 53
Disabled
Master Code (4 digits) + 54
Disabled
Master Code (4 digits) + 56
Enabled
Master Code (4 digits) + 021
Disabled
Master Code (4 digits) + 023
Master Code (4 digits) + 024 + Relay Output Time (0000-8000
.5 Seconds
Seconds) NOTE: Relay output time is ALWAYS 4 digits.
Master Code (4 digits) + 025 + Relay Output Time (0000-8000
.5 Seconds
Seconds) NOTE: Relay output time is ALWAYS 4 digits.