Environmental Specifications

Table 4 details environmental requirements for the R310 for operation and storage.
Temperature
Operating
Storage
Relative Humidity
Operating
Storage
Maximum Vibration
Operating
Dell PowerEdge R310 Technical Guide

Figure 19. Power Input Connectors

Environmental Requirements
Table 4.
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour (NOTE: For
altitudes above 2950 feet, the maximum operating
temperature is de-rated 1ºF/550 ft.)
–40° to 65°C (–40° to 149°F) with a maximum
temperature gradation of 20°C per hour
8% to 85% (non-condensing) with a maximum humidity
gradation of 10% per hour
5% to 95% (non-condensing)
0.25 G at 3–200 Hz for 15 min