Electrical Connection
■ This appliance must be earthed.
■ This appliance is designed to be connected to a 220~240V, 50/60Hz AC electricity supply.
■ The wires in the mains lead are coloured in accordance with the following code ;
- Green/yellow = Earth
- Blue
= Neutral
- Brown
= Live
■ The wire which is coloured green and yellow must be connected
to the terminal which is marked with the letter E or by the earth
symbol.
■ WIRING DIAGRAM
BLUE TO NEUTRAL
N
GREEN & YELLOW TO EARTH
GND
L
BROWN TO LIVE
�
MICRO SWITCHES
IGNITER
(INPUT: 220V 50~60HZ, OUTPUT: 15.25V)
23
CONNECTOR
1
N
2
3
L
4
�
N
Ignition
Electrode
L