Make Electrical Connection - Samsung NZ36M9880 Series Installation Manual

Hide thumbs Also See for NZ36M9880 Series:
Table of Contents

Advertisement

Available languages

Available languages

Make electrical connection

This cooktop is manufactured with ground wire (bare or green) connected to the
cooktop frame connect the cooktop cable to the junction box through the UL listed
or CSA approved conduit connector.
Electrical Connection Options
If your home has:
And you will be connecting to :
4-wire direct
Afused disconnect or circuit
breaker box
3-wire direct
Afused disconnect or circuit
breaker box
CHEF-INDU_NZ30M9880_NZ36M9880_DG68-00827B-01_EN+MES+CFR.indb 9
4-Wire Cable from Power Supply to 3-Wire Cable from Cooktop
IMPORTANT: Use the 4-wire cable from power supply where local codes do not
permit connecting the frame-ground conductor to the Neutral (N) junction box
wire.
Go to section:
4-Wire Cable from Power
supply to 3-Wire Cable
from Cooktop
A.
4-wire cable from power
supply
3-Wire Cable from Power
B.
L1 wires
supply to 3-Wire Cable
Ground (G) or bare ground
C.
from Cooktop
wire (from cooktop)
D.
3-wire cable from cooktop
E.
Junction box
F.
N (normally White) wire (from
power supply)
G.
UL listed wire connector
L2 (normally Red) wires
H.
I.
UL listed or CSA approved
conduit connector
NOTE
• Usually L1 is Black, L2 is Red, Ground (G) is Green or bare wire and Neutral (N) is
White wire.
• Do not connect the bare ground wire to the Neutral (N) wire in the junction box.
1. Disconnect power.
2. Remove Junction box cover if present.
3. Connect the flexible cable condult from
the cooktop to the junction box using
a UL listed or CSA approved condult
connector.
4. Tighten screws on condult connector, if
present.
5. Connect the two L2 wires together using
the UL listed wire connectors.
6. Connect the two L1 wires together using
the UL listed wire connectors.
7. Connect the Ground (G) or bare ground
wire from the cooktop cable to the
Ground (G) or bare ground wire (in the
junction box) using a UL listed wire
connectors.
8. Put a UL listed wire connector on the
end of the Neutral (N) wire.
9. Install junction box cover.
10. Reconnect power.
English 9
5/25/2018 7:07:52 PM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nz30m9880 seriesNz36m9880ub

Table of Contents