Maintenence Analysis Procedures
McDATA Sphereon 4500 Fabric Switch Installation and Service Manual
3-14
2
As indicated by event code 400, POST/IPL diagnostics detected a
FRU failure.
a. At the Event Log, examine the first two bytes of event data.
b. Byte 0 specifies failed FRU. Byte 1 specifies the slot number of
the failed FRU (00 for nonredundant, 00 or 01 for redundant) as
listed in
Table
3-6.
Table 3-6

MAP 200 Byte 0 FRU Codes

Byte 0
Failed FRU
02
CTP card.
05
Fan module.
06
Power supply.
3
A fan module or power supply failed POSTs and the power supply
(containing the fan, if applicable) must be removed and replaced.
Refer to
RRP 2: Redundant Power
The procedure is concurrent and performed while the product is
operational.
If multiple fan failures caused a thermal shutdown, connect the
product to facility AC power after power supply(s) are replaced.
Perform a data collection as part of FRU removal and
replacement. Refer to
Edition) or
Collect Maintenance Data
NOTE: Do not remove a power supply unless a replacement FRU is
available. To avoid product overheating, a removed power supply must be
replaced within five minutes.
Was the maintenance action successful?
NO
YES
The product is operational. Exit MAP.
Contact the next level of support. Exit MAP.
Action
Replace the switch. Exit MAP.
Go to
step
3.
Go to
step
3.
Supply.
Collect Maintenance Data
(Element Manager).
(EFCM Basic